CVE-2021-37162

moderate-risk
Published 2021-08-02

A buffer overflow issue was discovered in HMI3 Control Panel in Swisslog Healthcare Nexus Panel operated by released versions of software before Nexus Software 7.2.5.7. If an attacker sends a malformed UDP message, a buffer underflow occurs, leading to an out-of-bounds copy and possible remote code execution.

Do I need to act?

~
7.6% chance of exploitation in next 30 days
EPSS score — moderate exploit probability
-
Not on CISA KEV list
No confirmed active exploitation reported to CISA
?
Patch status unknown
Check vendor advisories for fix availability and mitigation guidance
9
CVSS 9.8/10 Critical
NETWORK / LOW complexity

Affected Products (1)

Hmi-3 Control Panel Firmware

Affected Vendors

47
/ 100
moderate-risk
Severity 32/34 · Critical
Exploitability 10/34 · Low
Exposure 5/34 · Minimal