CVE-2023-51585
moderate-risk
Published 2024-05-03
Voltronic Power ViewPower USBCommEx shutdown Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation. The specific flaw exists within the shutdown method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22071.
Do I need to act?
-
0.57% chance of exploitation
EPSS score — low exploit probability
-
Not on CISA KEV list
No confirmed active exploitation reported to CISA
?
Patch status unknown
Check vendor advisories for fix availability and mitigation guidance
8
CVSS 8.8/10
High
NETWORK
/ LOW complexity
Affected Products (1)
Affected Vendors
References (2)
Third Party Advisory
https://www.zerodayinitiative.com/advisories/ZDI-23-1890/
Third Party Advisory
https://www.zerodayinitiative.com/advisories/ZDI-23-1890/