CVE-2019-18336

moderate-risk
Published 2020-03-10

A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.

Do I need to act?

-
0.25% chance of exploitation
EPSS score — low exploit probability
-
Not on CISA KEV list
No confirmed active exploitation reported to CISA
?
Patch status unknown
Check vendor advisories for fix availability and mitigation guidance
7
CVSS 7.5/10 High
NETWORK / LOW complexity

Affected Products (12)

Simatic S7-300 Cpu Firmware
Simatic S7-300 Cpu 312 Ifm Firmware
Simatic S7-300 Cpu 313 Firmware
Simatic S7-300 Cpu 314 Firmware
Simatic S7-300 Cpu 314 Ifm Firmware
Simatic S7-300 Cpu 315 Firmware
Simatic S7-300 Cpu 315-2 Dp Firmware
Simatic S7-300 Cpu 316-2 Dp Firmware
Simatic S7-300 Cpu 318-2 Firmware
Sinumerik 840D Sl
Simatic Tdc Cp51M1 Firmware
Simatic Tdc Cpu555 Firmware

Affected Vendors

44
/ 100
moderate-risk
Severity 26/34 · High
Exploitability 1/34 · Minimal
Exposure 17/34 · Moderate